Coconut Creek's growing commercial base along State Road 7 and Lyons Road, including office parks and retail centers, has driven steady demand for electric strike installation, a key building block for access-controlled commercial doors throughout the city. This page explains the technology in plain terms: what an electric strike is, how it works with the rest of a door, how to choose the right type, what installation involves, and what property managers and business owners should plan for.
Broward County Locksmith is a mobile locksmith serving Broward County, Florida, including Coconut Creek. To discuss an access-controlled door, call (954) 888-8800.
What an Electric Strike Is
On an ordinary door, the latch or bolt enters a metal plate in the frame called a strike. A conventional strike is a fixed piece of metal with a hole. An electric strike replaces it with a device that can hold the latch or let it go, depending on whether it receives an electrical signal.
When the strike is in its locked state, the latch cannot leave the frame and the door stays shut. When someone with permission presents a credential, or a receptionist presses a release button, the strike receives power and its internal gate or keeper moves aside. The door can then be pulled or pushed open, without anybody turning a key or handle on the outside.
The lock hardware on the door itself is normally unchanged. The electric strike controls when the door can be opened from outside, and the handle or lever on the inside continues to let people out.
The Idea Behind It
Electric strikes make it possible to have a door that is always locked from outside, yet can be opened remotely or with a credential. They are popular for:
- Office suites where a receptionist buzzes in visitors.
- Rear or side entries used by staff with a keypad or card.
- Shared building doors where tenants have their own credentials.
- Medical and professional offices that need to control who comes into the back area.
- Retail stockrooms or restricted areas.
- Any location where handing out metal keys is a nuisance or a risk.
Fail-Secure and Fail-Safe: The Most Important Choice
Every electric strike is either fail-secure or fail-safe, and knowing the difference is essential.
Fail-secure
The strike stays locked when power is off. It needs power to unlock. During a power outage, the door stays locked from outside, but people can still exit because the inside lever or exit device retracts the latch mechanically. Fail-secure strikes are widely used on exterior doors and doors that must remain secure at all times.
Fail-safe
The strike stays locked as long as power is on, and unlocks when power is lost. During an outage, the door can be opened from outside. Fail-safe strikes are used where the door must unlock in an emergency, and are chosen based on the requirements of the door and the building.
Which one is right depends on the door's purpose, the applicable codes, and the building's needs. That decision belongs together with the building owner, the authority that governs the building, and a qualified professional. A locksmith can describe how each option behaves and what is typically used on a given kind of door.
Latch Types and Strike Compatibility
The strike must match the lock it works with.
- Spring latch. A standard angled latch. Many strikes are designed for this type.
- Deadlatch. A latch with a guard bolt. The strike must be compatible with the plunger.
- Mortise lock latch. Common on commercial doors. Requires the right strike model.
- Cylindrical lock latch. Commonly used in offices, with lever handles.
- Rim exit device latch. Uses a surface-mounted latch and needs a rim strike.
- Deadbolt. Bolts require a different type of strike, and not all electric strikes hold a deadbolt.
Buying a strike without confirming the lock type is a common cause of failures.
Types of Electric Strikes
- Standard cutout strikes. Installed in a routed opening in the frame, replacing the existing strike.
- Surface-mounted strikes. Attach to the outside of the frame with limited cutting, useful for metal frames or where the frame cannot be routed.
- In-line strikes. Fit into the frame with a narrow profile, suitable for narrow stile doors.
- Heavy-duty strikes. Built for high traffic and forceful use.
- Strikes with monitoring. Include switches that report whether the latch is engaged or the strike is unlocked.
Power and Wiring
An electric strike needs a power source. Typically that is a low-voltage power supply that converts building power to the level the strike needs. The strike is wired back to a control point, such as a keypad, card reader, or release button. Because the strike is part of a circuit, wire size and length matter. A long run with thin wire can drop voltage and leave the strike weak or unreliable. Good practice includes:
- Using the right size and type of wire for the run.
- Placing the power supply where it can be reached for service.
- Protecting the wiring in the door and frame, using a transfer hinge or door loop where wires cross from frame to door.
- Adding surge protection where appropriate.
- Labeling wires and keeping a wiring record.
Control Options
The strike does not decide who gets in. Something else must tell it when to release.
- Buzzer or release button. A person presses a button at a desk, and the strike releases for a moment.
- Keypad. A person enters a code.
- Card or fob reader. A person presents a credential.
- Intercom. A person inside speaks with a visitor and releases the door.
- Networked access control. Credentials are managed by software, with logs and schedules.
- Timers and schedules. The strike may remain unlocked during business hours for public entry, then lock after hours.
A locksmith usually handles the door side of these systems and works with the control system's installer or administrator where they are different parties.
The Installation Process
- Site review. The locksmith looks at the door, frame, and lock type, and asks how you want the door to operate.
- Selection. A strike is chosen to suit the lock, frame, and requirements.
- Planning the power and wiring. The route for wires and the location of the power supply are decided.
- Preparing the frame. The frame is cut or prepared to receive the strike. Care is taken because metal and aluminum frames need specific tools and methods.
- Mounting the strike. It is fitted, aligned with the latch, and secured.
- Wiring. The strike is connected to the power supply and the control device.
- Alignment and adjustment. The strike is adjusted so the latch enters and releases smoothly, with the door closing properly.
- Testing. The locksmith tests the strike under normal and abnormal conditions, including loss of power where relevant.
- Training. The people who will use the system are shown how it works.
Getting the Alignment Right
The most common reason for electric strike trouble is alignment. The latch must enter the strike opening smoothly, and the door must close with the latch held in place. If the door sags, the frame shifts, or the strike is set slightly off, the latch may bind. That can prevent the strike from releasing when it should, or cause it to release incorrectly. A properly aligned strike releases with little effort and closes without slamming.
Door Preparation: Not Just the Strike
A strike needs a door that closes reliably. Before installation, check:
- Hinges that are tight and not worn.
- A door closer that pulls the door fully shut without slamming.
- A frame that is sound and fastened securely.
- A latch that operates freely.
- Weatherstripping that does not prevent the door from latching.
If the door does not close by itself, the strike will not be able to lock it. A door closer is often part of an electric strike installation for that reason.
Life Safety and Exit
Electric strikes and exit rules go together. In general, a person inside a building must be able to leave without special knowledge or a key. On most doors with an electric strike, exit is provided by a lever, panic bar, or other hardware that retracts the latch mechanically. It must keep working when the power fails. Do not add features that block exit. The requirements that apply to a specific door depend on how the building is used and on the codes that govern it, so confirm them with the appropriate authority or a qualified professional before finalizing the design.
Security Considerations
An electric strike adds control, and there are ways to make it stronger.
- Use a strike rated for the door's use and, if needed, forced-entry resistance.
- Reinforce the frame, since the strike is only as strong as the frame around it.
- Protect the wiring, especially outside the building, so that it cannot be cut or tampered with.
- Mount the release button or reader where it cannot be reached through a gap or opening.
- Avoid leaving the system in an unlocked state for extended periods.
- Keep a mechanical key override with careful key control.
- Use a power supply with battery backup where appropriate.
Office Parks and Retail Centers in Coconut Creek
Commercial properties along the city's main corridors have a range of door situations.
- Multi-tenant office buildings may have a main entrance that is unlocked during business hours and locked after, and individual suite doors that use strikes for tenant control.
- Retail centers typically have service and stockroom doors that benefit from electronic control.
- Medical and professional offices often have a waiting room and a private area, with a strike separating them.
- Warehouses and flex space may use strikes on office entrances.
Each has its own priorities, but the same principles apply.
Frame Materials and What They Mean for the Cut
The frame around the door affects how a strike is installed.
- Hollow metal frames are common in commercial buildings. They are cut with the right tools, and the strike is fastened into the frame using proper reinforcement. Fitting a strike without reinforcing a thin frame can lead to bending over time.
- Aluminum storefront frames are narrow, so in-line or specially designed strikes are often needed. Cutting must be careful to avoid weakening the frame.
- Wood frames are easier to cut, but need firm anchoring so the strike does not loosen with repeated use.
A locksmith identifies the frame first, since that determines which strikes are practical.
Humidity and Weather in South Florida
Coconut Creek's warm, humid climate affects electronics and hardware. Exterior doors and strikes exposed to rain and moisture need parts rated for the conditions. Wiring connections must be sealed against moisture, since corrosion at a connection is a common cause of intermittent failures. Choose weather-resistant models for outdoor doors, and place power supplies indoors or in protective enclosures. Storms can cause power interruptions and surges, so surge protection and backup power are worth considering.
Troubleshooting a Strike That Does Not Behave
If a strike is not working, a few observations help narrow the cause.
- No click or movement when released. The strike may not be getting power, or the control device may have failed.
- Clicks but the door will not open. The latch may be binding against the strike, often because the door has shifted or is under pressure.
- Door opens without release. The strike may be unlocked because of a wiring problem, a fail-safe setting, or a latch that is not being held.
- Works sometimes and not others. Loose wiring, voltage drop, or a door that does not seat consistently are common causes.
- Buzzing or humming. Some strikes hum by design, but constant buzzing can indicate a power supply issue or mismatch.
Do not force a door that is under pressure against the latch. Ease the pressure and try again, or call a professional.
Planning for Growth
Businesses change. A small office may become a larger one. Plan a strike installation with future needs in mind, including the possibility of more doors, more users, and a network system later. Choosing hardware and wiring that can grow avoids rework. Keep clear records of the power supply capacity, wiring routes, and credential information.
Working With Landlords and Property Managers
In leased space, changes to a door may need approval. Ask the landlord what is allowed, what must be restored when the lease ends, and who is responsible for maintaining the system. If the building already has an access control system, your strike may need to integrate with it. Provide the locksmith with information about the existing system, or introduce them to the person who administers it.
Maintenance
- Test the strike periodically, and any time the door starts behaving differently.
- Clean the strike and latch area of dirt and debris.
- Check screws and mounting.
- Test the backup power source.
- Inspect wiring for damage.
- Verify that the mechanical override works.
- Keep the door closer adjusted properly.
Common Mistakes
- Choosing fail-safe when fail-secure was needed, or the reverse.
- Buying a strike that does not fit the latch type.
- Using long, thin wiring that causes voltage drop.
- Skipping door and frame checks, then blaming the strike.
- Installing a strike on a door that does not close by itself.
- Blocking or disabling the inside exit.
- Forgetting a backup plan for outages.
What to Prepare Before Calling
- The name and address of the property and which door needs the strike.
- The type of door: glass, aluminum, hollow metal, or wood.
- The type of lock now on the door.
- How you want to control entry: buzzer, keypad, card reader, or a combination.
- Whether the door is an exit for the building.
- Whether there is an existing access control system.
- Who can approve the work.
Serving Coconut Creek
Broward County Locksmith serves Coconut Creek businesses and property managers, and the rest of Broward County. Work is quoted before it begins. Call (954) 888-8800.
Frequently Asked Questions
What does an electric strike do?
It replaces the fixed strike in the door frame, and can hold or release the latch on command.
Is an electric strike the same as an electric lock?
Not exactly. The lock hardware stays on the door. The strike controls whether the latch can leave the frame.
What is the difference between fail-safe and fail-secure?
Fail-secure stays locked when power is off. Fail-safe unlocks when power is off. The choice depends on how the door is used and on safety requirements.
Can an electric strike work with any lock?
No. It needs to match the latch type. A locksmith checks compatibility before installation.
Will people be able to exit during a power outage?
On most installations, yes, since the inside hardware retracts the latch mechanically. Confirm this during design.
Do I need a door closer?
In most cases, yes. The door must close fully for the strike to hold it.
How does the strike know who to let in?
A separate control, such as a keypad, reader, or button, sends the signal.
Can an electric strike be added to an existing door?
Usually yes, if the frame can be prepared and the lock is compatible.
How long do electric strikes last?
It depends on quality and use. Heavy-duty models last longer on busy doors, and regular maintenance helps.
Is battery backup necessary?
It is a good idea for doors where an outage would cause a problem. Discuss it with your locksmith.
Can it be part of a larger access control system?
Yes. Strikes are commonly used with networked systems.
Do you serve areas outside Coconut Creek?
Yes. Broward County Locksmith serves communities throughout Broward County.
Choosing between fail secure and fail safe operation
An electric strike replaces the fixed plate in the door frame with one that can release on command, so a person can be buzzed in without a key. The first decision is how it behaves when power is lost. A fail secure strike stays locked without power, which suits doors that must remain protected during an outage. A fail safe strike unlocks without power, which can suit a stairwell or an exit path. Mixing these up is a common error, and it is worth thinking through what you want to happen on a stormy afternoon in Coconut Creek when the grid drops and the backup battery is nearly empty.
Life safety also enters the discussion. Doors that serve as exits must still let people leave freely, and the strike is only the entry side of that equation. Inside the building, a handle or panic hardware normally allows exit regardless of what the strike is doing. The technician reviews the latch type, because a strike works with a certain latch design, such as a cylindrical or mortise lock, and not every combination suits every frame. They also confirm that the building owner, tenant or property manager has authority to modify the opening, since altering a door in a shared building may need approval.
Voltage and control come next. Strikes run on low voltage direct current or alternating current, and the power supply, wire gauge and distance from the controller all affect how well the strike behaves. A strike that chatters or buzzes often has an undersized supply or a long, thin wire run. The technician asks how it will be controlled, whether by a push button, a keypad, a card reader or an intercom, and sizes the system around that. Describing your setup on the phone helps us plan. Quotes are given by phone, and the service call charge for a visit is explained before dispatch.
Frame prep, wiring, testing and keeping it dependable
Installation involves cutting the frame precisely. The existing strike pocket is enlarged to fit the new body, and the technician checks that the pocket sits flush and that the latch bolt lands squarely in the opening. Misalignment of even a small amount causes sticking, because the electric strike has less tolerance than a plain plate. Metal frames need careful filing to prevent burrs, and wood frames may need reinforcement so the strike does not loosen over time. Wires are routed neatly inside the frame or through a raceway, then connected to the power supply and control device with attention to polarity and a protective diode where needed.
Testing happens in stages. First the strike is powered on a bench or in the frame without the door closed, to confirm it clicks and releases. Then the door is closed and tested repeatedly with the actual controller. The technician watches how the latch rides over the strike, listens for buzzing and checks that the door relocks reliably each time. Coconut Creek weather adds a factor, since humidity, rain on exterior doors and salt carried on the breeze can attack contacts and screws. Using weather rated components and sealing penetrations around the frame helps the strike last through many wet seasons.
After the job, ask for a brief walkthrough. You should know how to release the strike manually if the controller fails, where the power supply sits, and what a healthy click sounds like. Keep a mechanical key for the lock handy as a backup, and test the whole system after any power outage or hurricane. If the strike starts to stick, hum or fail intermittently, call us before it stops completely. Our 24-Hour Emergency service can help with a door that will not secure, though you should call to confirm availability for your area.
More questions answered
What is the difference between fail safe and fail secure?
A fail secure strike stays locked when power is lost, while a fail safe strike unlocks without power. The right choice depends on the door and on safety rules. Exit doors usually need unobstructed exit from inside regardless of power. We help you think through the choice when you call.
Can an electric strike be added to any door?
Not every door suits every strike. The latch type, frame material and door condition all matter, and some frames need reinforcement. A technician checks the opening before recommending a model. Authority to modify the door is also confirmed, especially in shared or leased buildings. Bring up your door type, frame material and how many people use it, and we will talk through whether a strike fits before anyone is sent out.
Why does my strike buzz or stick?
Buzzing often points to the wrong power type, an undersized supply or a long thin wire. Sticking usually comes from slight misalignment between the latch and the strike pocket. Humidity can also corrode parts. A technician can test the voltage and alignment and tell you which one is the cause.
Recent Comments